Technical data

Industrial PC C6515

Dimensions (W x H x D):

240 x 230 x 81 mm

Weight: 3.03

kg

Do not use the PC in areas
of explosive hazard

The Industrial PC may not be used in areas of explosive hazard.

The following conditions must be observed during operation:

Environmental conditions

Ambient temperature:

Outside: 0 to 45°C

Inside:

0 to 55°C

Atmospheric humidity:

Maximum 95%, non-condensing

Shock resistance

Sinusoidal vibration:

(EN 60068-2-6)

10 to 58 Hz:

0.035 mm

58 to 500 Hz: 0.5 G (~ 5 m/ s

2

)

Impact:
(EN 60068-2-27/ -29)

5 G (~ 50 m/ s²), duration: 30 ms

Protection class

Protection class:

Outside:

IP65

Inside:

IP20

Power supply
24 V

DC

power pack

Supply voltage: 22–30V

V

DC

Power consumption:

approx. 90 W (basic configuration)

When operated with UPS:

additional 30 W (while charging)

additional 44 W (with UPS-output)

Electromagnetic
Compatibility (EMC)

Interference resistance:

according to EN 61000-6-2

Emitted resistance:

according to EN 61000-6-4

Transport and storage

The same values for atmospheric humidity and shock resistance are to be
observed during transport and storage as in operation. The shock
resistance during transport can be improved by means of suitably packing
the Industrial PC. The ambient temperature during storage and transport
must be between -20°C and +65°C.

Approvals

FCC: Federal Communications Commission
Radio Frequency Interference Statement

FCC Approval for USA

This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own
expense.

FCC: Canadian Notice

FCC Approval for Canada

This equipment does not exceed the Class A limits for radiated emissions
as described in the Radio Interference Regulations of the Canadian
Department of Communications.