Warning, Site selection and preparation – Dimplex 30" FIREPLACE User Manual
Page 6
NOTE
A 15amp, 120 volt circuit is required. A dedicated circuit is preferred but not essential in all
cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or fuse
blows on a regular basis when the heater is operating. Additional appliances on the same
circuit may exceed the current rating of the circuit breaker.
WARNING
Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure
that the power cord is stored or secured to avoid tripping or snagging to reduce the risk of fire,
electric shock or injury to persons.
Construction and electrical outlet wiring must comply with local building codes and other
applicable regulations to reduce the risk of fire, electric shock and injury to persons.
Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric
shock or injury to persons, always use a licensed electrician.
SITE SELECTION AND PREPARATION
This section provides easy step by step instructions for selecting a location and preparing the
site to install the fireplace into:
•
Existing Fireplace
•
New wall construction
•
Dimplex mantel surround kit or custom made mantel surround
NOTE
The fireplace insert comes completely assembled and wired. Some tools may be required to
prepare the site and assembly/install the trim.
The dimensions of the fireplace insert are 30” wide X 25 ¼” high X 11 ¼” deep. (FIGURE 1)
You should allow ¼” around the fireplace insert for ease of installation.
This fireplace does not require any venting.
CAUTION
Clearance for air circulation beneath the fireplace insert is provided by three rubber feet (FIGURE 1).
DO NOT INSTALL THE FIREPLACE INSERT DIRECTLY ON CARPET OR SIMILAR
SURFACES WHICH MAY RESTRICT AIR CIRCULATION. If installing the fireplace in a
carpeted area, place a one-piece, solid, flat surface under the fireplace insert. Ensure that all
three of the insert’s feet rest securely on this surface.
3