o
Unscrew the injector and replace it with the required injector for
the new gas supply according to the table below.
Burner Type
Gas Type Pressure
Mbar
Injector
Marking
(1/100mm)
Power
(Kw)
Max Min
Oven Burner
Natural
Gas
20
1.15
2.1 0.8
Liquid Gas 28..30/37
0.72
Grill Burner
Natural
Gas
20
1.15
2.1 0.8
Liquid Gas 28..30/37
0.72
o
After changing the injectors YOU MUST change the minimum
flow rate.
Minimum flow adjustment for the oven and grill burners
All work must be carried out by a GASSAFE
registered engineer.
o
In order to access the adjusting screws to change the minimum
flow rate of the grill and oven burners, you need to remove the
hob top and control panel.