Control and setting throuth http command – Aviosys 9216 User Manual
Page 21
IP SENSOR 9216 USER MANUAL
Click the Brower button to find the corresponding update file (you can download it from our web site or ask it
from the dealer), then click Update button to start update firmware. When the update is finished, you must wait
one minute before you restart the IP Sensor 9216.
7. Control and setting throuth HTTP Command
User can read the value of 9216 from HTTP command ,the format of http command as follow :
http://username:[email protected]/Set.cmd?cmd=xxxxxx
the Definition of each part in command ;
username:9216 username, factory default value is admin.
password:9216 password , factory default value is admin.
XXX.XXX.XXX.XXX : IP address of 9216
Set.cmd?cmd=xxxxxxxx as command format as 9216.
Command as follow :
Command Description
GetInput16 : read status of DI
GetVolt : read status of voltage
GetTemp : read status of temperature
GetFan : read status of fan
9216 IP address is 192.168.100.99
type following command
http://admin:[email protected]/Set.cmd?cmd=GetInput16
you will get the following result :
Input:I1:1,I2:1,I3:1,I4:1,I5:1,I6:1,I7:1,I8:1,I9:0,I10:0,I11:0,I12:0,I13:0,I14:0,I15:0,I16:0,
1 means high voltage 0 means low voltage
so Input 1~8 is high voltage and Input 9~16 low voltage.