beautypg.com

Owner’s manual, Product identification local codes, Product features – Desa FMH26TP User Manual

Page 3: Unpacking, Safety information, Continued

background image

3

107106

OWNER’S MANUAL

PRODUCT IDENTIFICATION

LOCAL CODES

Install and use fireplace with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Figure 1 - Vent-Free Propane/LP Gas Compact Fireplace

PRODUCT
FEATURES

SAFETY PILOT

This fireplace has a pilot with an Oxygen
Depletion Sensing (ODS) safety shutoff sys-
tem. The ODS/pilot is a required feature for
vent-free room fireplaces. The ODS/pilot shuts
off the fireplace if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This sys-
tem requires no matches, batteries, or other
sources to light fireplace.

THERMOSTATIC HEAT
CONTROL

This fireplace has a thermostat sensing bulb
and a control valve. The thermostat will
automatically modulate the heat output to
maintain a consistent room temperature.
This results in greater fireplace comfort.
This can also result in lower gas bills.

Ignitor Button

Screen

Fireplace
Cabinet

Logs

Control Knob

UNPACKING

1.

Remove log box and fireplace from
carton. The hood is not attached.

IMPORTANT:

The fireplace hood is

inside the cardboard protective end
wrap on the left side of fireplace (as
viewed from front). A decal is on the
outside of the cardboard end wrap stat-
ing hood is enclosed (see Figure 2).

2.

Remove hood from cardboard protec-
tive end wrap as shown in Figure 2.

3.

Remove all protective packaging ap-
plied to fireplace for shipment.

4.

Make sure your fireplace includes one
hardware packet.

5.

Check fireplace for any shipping
damage. If fireplace is damaged,
promptly inform dealer where you
bought fireplace.

SAFETY
INFORMATION

Continued

15. Operating fireplace above elevations of

4,500 feet could cause pilot outage.

16. Do not operate fireplace if any log is

broken. Do not operate fireplace if a
log is chipped (dime-sized or larger).

17. To prevent performance problems, do

not use propane/LP fuel tank of less
than 100 lbs. capacity.

18. Provide adequate clearances around air

openings.

IMPORTANT:

THIS PACKAGE CONTAINS A

FIREPLACE HOOD. UNWRAP

CARTON AND REMOVE HOOD

BEFORE DISCARDING

PROTECTIVE PACKAGING.

1

2

Figure 2 - Removing Fireplace Hood

Hood

Cardboard
Protective
Fireplace
End Wrap

Hood
Enclosed
Decal