INSTALLATION

CAUTION: The unit's power supply cord must be connected to a properly
grounded and protected 120-volt outlet. Always use ground fault protection where
required by the electrical code.

WARNING - RISK OF FIRE! To prevent a possible fire, do not block the grills,
louvers, or air openings on the fireplace insert in any manner.

WARNING - RISK OF FIRE! The power cord must not be pinched or placed
against a sharp edge. Secure the cord to avoid tripping or snagging thus reducing
the risk of fire, electric shock or personal injury. Do not run the cord under
carpeting. Do not cover the cord with throw rugs, runners or similar items.
Arrange the cord away from traffic areas where it could be tripped over.

Select a suitable location that is not susceptible to moisture and is away from drapes, furniture and high traffic areas.

Note: Follow all national and local electrical codes.

CLEARANCES WHEN BUILT-IN

WALL

FLOOR

FACE (required)

APPLIANCE
SIDE VIEW

1/2"[13 mm]

The fireplace insert may be placed within a framed enclosure that is level, dry, and capable of supporting the weight of the appliance

and front glass. It may be placed directly on wood or a non-combustible surface (not on linoleum or carpet).

MINIMUM 1/4" (7mm) CLEARANCE TO TOP

OF APPLIANCE( combustible or non-combustible)

MINIMUM 1" (25.4mm) CLEARANCE

TO BACK OF APPLIANCE

(combustible or non-combustible)

MINIMUM 1/2" (13mm) CLEARANCE

TO SIDES OF APPLIANCE

(combustible or non-combustible)

Make sure the mantel ( combustible or non-combustible)

is 1/2" (13mm) above the face. This allows for face

installation and removed.