Installation (for qualified installers only)
© Travis Industries
4140811
100-01331
Electrical Requirements
Travis Industries manufactures a wiring kit specifically for inserts (sku 97200315). This kit allows installers to
wire 120 volt AC power into a fireplace directly to the insert, eliminating the need for an external power cord.
Plug the power cord into a grounded 120 Volt outlet (do not remove the grounding pin).
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
Do not route the power over the appliance or near any hot or moving components.
Re-Routing the Power Cord to the Front of the Insert
The power cord is shipped attached to the side of the insert. It may be routed to the front where it exits
behind the face but in front of the surround panel. See the directions below for details.
Using the Insert Wiring Kit
When using the insert wiring kit, remove and discard the cover plate on the side of the insert. See the
instructions included with the wiring kit for attaching the kit to the side of the insert.
Power Cord
Remove the side
access panel.
Use pliers to remove
the strain relief.
Disconnect the molex connector and remove
the power cord from of the side location.
Re-attach the strain relief and power cord
to the forward location and re-connect
the molex connector.
a
b
c
d
Disconnect the molex connection
and remove the power cord.
c
d
Remove and discard the cover plate.
The wiring kit connects to the larger
hole on side of the insert
Power Cord
Remove the side
access panel.
Use pliers to
remove the
strain relief.
a
b