ATI Audio MCDA208 User Manual
Page 9
9
!
!
"#$%&'()!"*+,*-!
AES SYNC IN
Provides a balanced, transformer isolated 110 ohm AES Sync input that a derived Word Clock
may be routed to XLR Outputs 1 through 4, Outputs 5 through 8 or BNC Outputs 1 through 6 via
the configuration DIP switches. A Frame Clock is derived from this input. When present, this
signal provides first priority for synchronizing the internal Clock Generator when CLOCK
SOURCE SET is set to BY PRIORITY.
AES LOOP-THRU
Provides a convenient loop-thru port for the AES External Sync input. When looping this signal
to another device, set Input Termination to Off.
WORD CLOCK INPUT
Provides an isolated high impedance or 75 ohm Word Clock input to synchronize the internal
Clock Generator. It may be routed to XLR Outputs 1 through 4, Outputs 5 through 8 and/or BNC
Outputs 1 through 6 via the configuration DIP switches. When present, this signal provides the
second priority for synchronizing the internal Clock Generator when CLOCK SOURCE SET is
set to BY PRIORITY.
WORD CLOCK LOOP-THRU
Provides a convenient loop-thru port for the Word Clock input. When looping this signal to
another device, set Input Termination to Off.
CONFIGURATION DIP SWITCHES
Provides routing and other selections for signal flow in the unit. See the DIP Switch Routing
Table for settings:
The switches are labeled left to right BANK A switch “1” is “DIP Switch 1 in the following tables.
DIP Switches 7 through 12 have no function in the MCDA-208/DA106. In this view Outputs 1-4
are connected to input 1. OUTPUT 5 to 8 are connected to Word Clock generated by the
WORD CLOCK INPUT. The WCLK OUT 1 through 6 are connected the internal clock
generator.