INSTALLATION
LOCATION
The MCDA is readily installed into a 2 RU, 19” rack. The MCDA is only to be installed in an
inside location where it is protected from inclement weather. Operate the MCDA in temperature
range of +5 to +40°C (105°F), with relative humidity ranging from 5 to 85%.
POWER
Connector for socket fused IEC 320/C13. Power cord is supplied. The MCDA has a rear panel
On Off power switch.
POWER INPUT SPECIFICATIONS:
Voltage .......................................................................................85 ~ 264Vac
Frequency .....................................................................................47 to 63Hz
This equipment is connected to earth through the center conductor of the AC mains cable.
Proper grounding protects user/operators from electric shock, and it must be maintained
whenever the unit is connected to AC.
WIRING
BNC connectors use 75-ohm coax (RG59). Select a cable for losses less than 20dB at 12MHz
(for data rates up to 96 k samples) at the maximum distance you require. Keep cable length as
short as possible, especially when working with Super Word clock rates.