SPECIFICATIONS

INPUTS

Connectors:

XLR female or BNC, DC isolated from chassis.
Input connector pairs paralleled for loop-thru.

Level:

200mVp-p minimum

Impedance: Transformer isolated, capacitor coupled, balanced and

floating, XLR inputs 110 ohms, and BNC and RCA inputs 75
ohms.
Terminating resistors may be switched in or out on rear
panel.

 

Cable Length: 300m of 110-ohm cable, 1000 m of 75 ohm coax (with

equalizer)

 

Equalizer:

Multi-turn panel control, adjust using DSA panel indicators

 

Sample Rates:

Accepts 27kHz to >100kHz

 

DDA Clock:

Regenerated from input signal with dual-mode PLL Clock
Jitter <3nanoseconds peak-to-peak at 96kHz sample rate

 

DSA Clock:

Non-regenerated. Input clock is passed directly to outputs.

 

 

 

OUTPUTS

 

Connectors:

XLR male, 6 or 12; BNC chassis mount, 12 or 24

 

Levels: XLR, 4Vp-p loaded at 110 ohms. BNC, 2Vp-p loaded at 75

ohms, RCA, 0.5Vp-p loaded at 75 ohms

 

Impedances: XLR: 110 ohms, balanced, transformer isolated and

capacitor coupled

 

BNC:

75 ohms, unbalanced, capacitor coupled

 

Output Jitter:

<3 nanoseconds peak to peak at 96kHz sample rate

 

Output Delay:

Three frames (sample intervals) at the sample rate

This manual is related to the following products: