Westward Operating Instructions and Parts Manual

Model 3JR70A

Portable Air Compressor

Symptom (s)

Possible Causes (s)

Corrective Actions (s)

Motor will not

run.

1a. Check fuse box for

blown fuse and replace

as necessary.

Reset circuit breaker. Do

not use a fuse or circuit

breaker with higher

rating than that specified

for your particular branch

circuit.

b. Check for proper fuse.

You should use a time

delay fuse.

c. Check for low voltage

problem.

d. Check the extension

cord.

e. Disconnect the other

electrical appliances from

circuit or operate the

compressor on its own

branch circuit.

4. Have checked by

a trained service

technician.

1. Fuse blown, circuit

breaker tripped.

2. Extension cord is wrong

length or gauge.

3. Loose electrical

connections.

4. Faulty motor.

2. Check the extension

cord.

3. Check wiring connection

inside terminal box.