36
UPCE
Read: Format
Leading
Zero
Data Digits (6
Digits)
Check
Digits
Check-sum verification: The checksum of EAN-13 is
optional and made as the sum of the numerical value of the
data digits.
Check-sum transmission: By setting Enable, checks sum
will be transmitted.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
Enable
00
01
Check-sum
transmission
Disable
Enable
00
01
Program