Upca – Argox AS-8000 User Manual
Page 37
32
UPCA
Read: Format
Leading
Zero
Data Digits
(11 Digits)
Check
Digit
Check-sum transmission: By setting Enable, checks sum
will be transmitted.
Truncate leading/ending: The leading or ending digits of
barcode data characters can be truncated when these values
are set to non-zero. It will beep
instead of reading anything
when the truncate value is more than the barcode data digits
or the value of Truncate Leading is overlapped with that of
the Ending. The maximum value of truncate digits is 15.
Code ID setting: Code ID setting is a character used to
represent the symbol upon a succeeding reading. A Code ID
setting is prefixed to the data begin or end transmitted if the
feature is selected. If you want application to transmit Code
ID, you must set Code ID transmission to Enable first. Refer
to Code ID transmission.
Insertion group selection: The scanner offer one or two
insertion group for own symbology. By setting one or two
digits to indicate which insertion group you want to insert.
You may refer to Character insertion.
Example: Group 2 ൺ set 02 or 20.
Group 1 and 4 ൺ set 14 or 41.
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
Enable
00
01
Program