beautypg.com

Aplex Technology APC-3517B User Manual

Page 31

background image

APC-3X17B User Manual

31

LED2:

POWER LED

status.

S1:
PWR BT: POWER on/off Button
, They are used to connect power switch button. The

two pins are disconnected under normal condition. You may short them temporarily to
realize system startup & shutdown or awaken the system from sleep state.

PWR LED:

POWER LED

status.

COM3:

(Type DB9),I/O serial port, it provides selectable RS422/RS485 serial signal output.

RS422 Type (option)

RS485 Type (option)

Signal Name Pin#

Pin#

Signal Name

422_RX+ 1 1

NC

422_RX- 2 2

NC

422_TX- 3 3

485-

422_TX+ 4 4

485+

Ground

5 5

Ground

NC 6

6

NC

NC 7

7

NC

NC 8

8

NC

NC 9

9

NC

This manual is related to the following products: