Interface connector, Interface pinout, Optional interface connector accessories – AMETEK HPAL User Manual
Page 2

Technical Note
ReFlex Power™ Mating Connectors for HPAL/LPAL Module
Document No. W380273-01 Rev D •
1/23/2009
©2008 AMETEK Programmable Power, Inc. • All rights reserved. • AMETEK is a trademark of AMETEK, Inc.
9250 Brown Deer Road, San Diego CA 92121 • Tel: 858-450-0085 • Fax: 858-458-0267 • email:
• Web:
www.programmablepower.com
2 of 3
INTERFACE CONNECTOR
External isolated digital and analog control interface
Connector: Positronic Industries P/N SD9M1000Z, AMETEK P/N 856-214-09
Crimp contacts: Positronic Industries P/N MC7520D (initially supplied with connector)
Backshell: Positronic Industries P/N D9000Z00, AMETEK P/N 856-247-10
Wire size: Maximum gauge 20 AWG (22 AWG recommended)
Maximum length 10 meters.
INTERFACE PINOUT
Figure 2. Interface Connector, Front Panel View, and Interface Connector Wiring Diagram
Pin
Name Function
Signal
Level
1
ENA
1
Input: module output enable
TTL logic level
6
ENA-RTN
1
Input: return for ENA signal; connected to Pin-7/8
Signal common
2
Reserved
7
Reserved
3
Reserved
8
Reserved
4
MOD-IN-H
Input: external modulation signal; differential input with MOD_IN_L
5V/10V analog signal
9
MOD-IN-L
Input: return for external modulation signal, MOD_IN_H
5V/10V analog signal
5
CHAS-GND Shield
ground
Chassis
ground
1
Enable signal is internally pulled up to +5 V with a 10 K resistor. To enable the module, the signal is pulled low (<= 0.5 V) with respect to
the ENA RTN signal; this may also be accomplished by shorting Pin 1 to Pin 6.
OPTIONAL INTERFACE CONNECTOR ACCESSORIES
•
AMETEK P/N 5380508-01, 9-pin Loop-back Connector Assembly. Includes a jumper wire between Pins 1 and 6 to enable
the module outputs.
•
AMETEK P/N 5380443-01, Power Module, 9ft. Unterminated Interface Cable Assembly. Use when interfacing to an
external system.
•
AMETEK P/N 5380443-03, Power Module, Right Angle, 9ft. Unterminated Interface Cable Assembly. Use when interfacing
to an external system.