beautypg.com

Interface connector, Interface pinout, Optional interface connector accessories – AMETEK HPAL User Manual

Page 2

background image

Technical Note

ReFlex Power™ Mating Connectors for HPAL/LPAL Module

Document No. W380273-01 Rev D •

1/23/2009

©2008 AMETEK Programmable Power, Inc. • All rights reserved. • AMETEK is a trademark of AMETEK, Inc.

9250 Brown Deer Road, San Diego CA 92121 • Tel: 858-450-0085 • Fax: 858-458-0267 • email:

[email protected]

• Web:

www.programmablepower.com


2 of 3

INTERFACE CONNECTOR

External isolated digital and analog control interface

Connector: Positronic Industries P/N SD9M1000Z, AMETEK P/N 856-214-09

Crimp contacts: Positronic Industries P/N MC7520D (initially supplied with connector)

Backshell: Positronic Industries P/N D9000Z00, AMETEK P/N 856-247-10

Wire size: Maximum gauge 20 AWG (22 AWG recommended)

Maximum length 10 meters.

INTERFACE PINOUT

Figure 2. Interface Connector, Front Panel View, and Interface Connector Wiring Diagram

Pin

Name Function

Signal

Level

1

ENA

1

Input: module output enable

TTL logic level

6

ENA-RTN

1

Input: return for ENA signal; connected to Pin-7/8

Signal common

2

Reserved

7

Reserved

3

Reserved

8

Reserved

4

MOD-IN-H

Input: external modulation signal; differential input with MOD_IN_L

5V/10V analog signal

9

MOD-IN-L

Input: return for external modulation signal, MOD_IN_H

5V/10V analog signal

5

CHAS-GND Shield

ground

Chassis

ground

1

Enable signal is internally pulled up to +5 V with a 10 K resistor. To enable the module, the signal is pulled low (<= 0.5 V) with respect to

the ENA RTN signal; this may also be accomplished by shorting Pin 1 to Pin 6.

OPTIONAL INTERFACE CONNECTOR ACCESSORIES

AMETEK P/N 5380508-01, 9-pin Loop-back Connector Assembly. Includes a jumper wire between Pins 1 and 6 to enable
the module outputs.

AMETEK P/N 5380443-01, Power Module, 9ft. Unterminated Interface Cable Assembly. Use when interfacing to an
external system.

AMETEK P/N 5380443-03, Power Module, Right Angle, 9ft. Unterminated Interface Cable Assembly. Use when interfacing
to an external system.

This manual is related to the following products: