Reflex power™ mating connectors for acps module, Optional interface connector accessories, Ac output connector – AMETEK ACPS User Manual
Page 3: Ac output pinout

Technical Note
ReFlex Power™ Mating Connectors for ACPS Module
Document No. W380272-01 Rev D •
1/23/2009
©2008 AMETEK Programmable Power, Inc. • All rights reserved. • AMETEK is a trademark of AMETEK, Inc.
9250 Brown Deer Road, San Diego CA 92121 • Tel: 858-450-0085 • Fax: 858-458-0267 • email:
• Web:
www.programmablepower.com
3 of 4
OPTIONAL INTERFACE CONNECTOR ACCESSORIES
•
AMETEK P/N 5380508-01, 9-pin Loop-back Connector Assembly. Includes a jumper wire between Pins 1 and 6 to
enable the module outputs.
•
AMETEK P/N 5380443-01, Power Module, 9ft. Unterminated Interface Cable Assembly. Use when interfacing to an
external system.
•
AMETEK P/N 5380443-03, Power Module, Right Angle, 9ft. Unterminated Interface Cable Assembly. Use when
interfacing to an external system.
AC OUTPUT CONNECTOR
Connector: Positronic Industries P/N CBD13W6M2000Z, AMETEK P/N 856-214-07
Pins A1-A6:Positronic Industries P/N MS4820D-50, AMETEK P/N 856-745-53
Pins 1-7:
supplied with connector
Backshell: Positronic
Industries
P/N D37000Z00/ AMETEK P/N 856-247-39
Wire size:
Pins A1 through A4 maximum gauge 20 AWG (recommended); maximum length 15 ft (Voltage drop at full-rated current
≅1.1V)
Pins A5, A6 maximum gauge 20 AWG (recommended); maximum length 15 ft
Pins 2, 6 maximum gauge 20 AWG (recommended); maximum length 15 ft (Voltage drop at full-rated current
≅0.6V)
AC OUTPUT PINOUT
A1
A2
A3
A4
A5
A6
2
6
4
AC Output
Out
N/U
Chas Gnd
Aux_Rtn
Aux
Sense_Rtn
Sense
Out_Rtn
Out
Out_Rtn
5
3
1
7
N/U
N/U
N/U
T/P
T/P
T/P
T/P
T/P
T/P
Load
Aux Load
T/P = Twisted Pair; N/U = Not Used
T/P
T/P
Figure 3. AC Output Connector, Front Panel View, and AC Output Connector Wiring Diagram
Pin
Name Function
Signal
Level
A1
Out
Output: module output source; connected to A3
280VAC;
±440V
PK
, maximum to chassis
A2
Out_Rtn
Output: return for output source, OUT; connected to A4
280VAC;
±440V
PK
, maximum to chassis
A3
Out
Output: module output source; connected to A1
280VAC;
±440V
PK
, maximum to chassis
A4
Out_Rtn
Output: return for output source, OUT; connected to A2
280VAC;
±440V
PK
, maximum to chassis
A5
Sense
Input: remote sense connection for OUT
280VAC;
±440V
PK
, maximum to chassis
A6
Sense_Rtn
Input: remote sense connection for OUT-RTN
280VAC;
±440V
PK
, maximum to chassis
2
Aux
Output: Module auxiliary output source:
35VAC;
±100V
PK
, maximum to chassis
6
Aux_Rtn
Output: return for auxiliary output source, Aux.
35VAC;
±100V
PK
maximum to chassis
4
Chas Gnd
Shield Ground
Chassis Ground