beautypg.com

Reflex power™ mating connectors for acps module, Optional interface connector accessories, Ac output connector – AMETEK ACPS User Manual

Page 3: Ac output pinout

background image

Technical Note

ReFlex Power™ Mating Connectors for ACPS Module

Document No. W380272-01 Rev D •

1/23/2009

©2008 AMETEK Programmable Power, Inc. • All rights reserved. • AMETEK is a trademark of AMETEK, Inc.

9250 Brown Deer Road, San Diego CA 92121 • Tel: 858-450-0085 • Fax: 858-458-0267 • email:

[email protected]

• Web:

www.programmablepower.com


3 of 4

OPTIONAL INTERFACE CONNECTOR ACCESSORIES

AMETEK P/N 5380508-01, 9-pin Loop-back Connector Assembly. Includes a jumper wire between Pins 1 and 6 to
enable the module outputs.

AMETEK P/N 5380443-01, Power Module, 9ft. Unterminated Interface Cable Assembly. Use when interfacing to an
external system.

AMETEK P/N 5380443-03, Power Module, Right Angle, 9ft. Unterminated Interface Cable Assembly. Use when
interfacing to an external system.

AC OUTPUT CONNECTOR

Connector: Positronic Industries P/N CBD13W6M2000Z, AMETEK P/N 856-214-07

Pins A1-A6:Positronic Industries P/N MS4820D-50, AMETEK P/N 856-745-53

Pins 1-7:

supplied with connector

Backshell: Positronic

Industries

P/N D37000Z00/ AMETEK P/N 856-247-39

Wire size:

Pins A1 through A4 maximum gauge 20 AWG (recommended); maximum length 15 ft (Voltage drop at full-rated current

≅1.1V)

Pins A5, A6 maximum gauge 20 AWG (recommended); maximum length 15 ft
Pins 2, 6 maximum gauge 20 AWG (recommended); maximum length 15 ft (Voltage drop at full-rated current

≅0.6V)

AC OUTPUT PINOUT

A1
A2
A3
A4
A5
A6

2
6
4

AC Output

Out

N/U

Chas Gnd

Aux_Rtn

Aux

Sense_Rtn

Sense

Out_Rtn

Out

Out_Rtn

5

3

1

7

N/U

N/U

N/U

T/P

T/P

T/P

T/P

T/P

T/P

Load

Aux Load

T/P = Twisted Pair; N/U = Not Used

T/P

T/P

Figure 3. AC Output Connector, Front Panel View, and AC Output Connector Wiring Diagram

Pin

Name Function

Signal

Level

A1

Out

Output: module output source; connected to A3

280VAC;

±440V

PK

, maximum to chassis

A2

Out_Rtn

Output: return for output source, OUT; connected to A4

280VAC;

±440V

PK

, maximum to chassis

A3

Out

Output: module output source; connected to A1

280VAC;

±440V

PK

, maximum to chassis

A4

Out_Rtn

Output: return for output source, OUT; connected to A2

280VAC;

±440V

PK

, maximum to chassis

A5

Sense

Input: remote sense connection for OUT

280VAC;

±440V

PK

, maximum to chassis

A6

Sense_Rtn

Input: remote sense connection for OUT-RTN

280VAC;

±440V

PK

, maximum to chassis

2

Aux

Output: Module auxiliary output source:

35VAC;

±100V

PK

, maximum to chassis

6

Aux_Rtn

Output: return for auxiliary output source, Aux.

35VAC;

±100V

PK

maximum to chassis

4

Chas Gnd

Shield Ground

Chassis Ground