Maintenance
If the Callisto’s volume controls are adjusted manually, the Remove Volume
Control will sense and track the changes. From time to time it is possible that the
display will be inaccurate relative to the position of the volume control. If this
happens, manually turn both of the volume controls of the Callisto to 0, unplug
the AC power to the Remote Volume Control – wait 10 seconds and then
reconnect the AC power. The display on the Remote Volume Control should
read 0 for both channels (one 0 in the center). Using the hand held remote
control, bring up the volume.
The Remote Volume Control does not require any internal field maintenance. Do
not, under any condition, remove the top cover. Refer all service to Aesthetix
authorized service personnel.
Specifications
Fuses:
Internal fuse
3/8 amp slow blow (100-117v)
1/4 amp slow blow (220-240v)
Power Consumption:
<50W both motors driven
Dimensions:
8 1/2" Width x 7 3/4" Depth x 2 5/8" Height
216mm Width x 197mm Depth x 67mm Height
Shipping Weight:
6 lbs (2.7 Kg)