ATTACHING THE SENSOR FLEXIBLE CABLES
The flexible cable bend radius at the sensor edge, and along the cable length, should be a minimum of
2.5mm, as shown in Figure 15.
FLEXIBLE CABLE BENDING AT SENSOR EDGE
The flexible cables should be plugged into the controller PCB, as shown in Figure 16.
FLEXIBLE CABLES PLUGGED INTO THE CONTROLLER PCB
The gold contact side of the flexible cable should be visible, as depicted on the label shown in
Figure 17.
MINIMUM 2.5MM RADIUS
FIGURE 15
FIGURE 16