10. Back-to-Back Test

Press the test launch button to start the Back-to-Back test. The individual test tab for

the Back-to-Back test will show after the test launch button is clicked.

Back-to-Back Test measures the buffer capacity of the DUT by sending bursts of traffic

at the maximum frame rate and by measuring the longest burst size for which no

packets are dropped. For each packet length specified in test setup, the test is

automatically repeated to provide an accurate view of the buffer capacity of the DUT

under different conditions.

Use the tabs at the bottom of the window to activate the individual Back-to-Back test

tab. To end the test, press

. Press

to return to the main window.