Long-term storage, Troubleshooting, Specifications – Toyotomi TD-Z110 User Manual
Page 6
CAUTION
•
NEVER use gasoline, solvents, chemical products or polish as
they could damage the surface.
5. LONG-TERM STORAGE
At the end of each season, or when you do not plan to use your
unit for an extended period of time, the following procedures are
recommended.
1.
Turn off the unit, wait for it to stop and unplug from the power
socket.
2.
Clean and dry the water tank. Leave the unit to drain for ap-
proximately one day.
3.
Clean the filter and the unit. Cover the unit to prevent it from
gathering dust. Store upright in a cool dry place. DO NOT ex-
pose to direct sunlight.
CAUTION
•
ALWAYS store the unit in the vertical position.
•
DO NOT put heavy objects on top of the unit.
6. TROUBLESHOOTING
BEFORE CALLING FOR SERVICE
The followings are not defects.
7. SPECIFICATIONS
3
ENGLISH
MODEL
TD-Z110
DEHUMIDIFYING CAPACITY
11 L/D (20˚C/60%rh)
POWER SOURCE
Single Phase 220V~240V, 50Hz
POWER CONSUMPTION
740 W (High) / 400 W (Low)
OPERATING CURRENT
3.2 A
WATER TANK CAPACITY
3.8 L
OPERATING TEMP. RANGE
1˚C ~ 40˚C
DIMENSIONS (WxHxD)
217 x 528 x 462 mm
WEIGHT
8.2 kg
SYMPTOM
The dehu-
midifier is
noisy.
The fan runs
after turning
the unit off.
Check / Low
humidity
lamp (C7)
lights
CAUSE
- The air filter is blocked
or the unit is on an
uneven surface.
- The fan is cooling the
internal heater.
- The filter is clogged
- Something is shutting
on the air intake or the
air outlet.
- The room humidity is
low
SOLUTION
- Clean the filter and or
put the dehumidifier
on a flat surface. A
dehumidifier will also
be noisier on wooden
floors than on carpet.
- This is normal and the
fan will run for about 2
minutes after you
press the Power but-
ton to turn the unit off.
Never turn the unit off
at the wall until the fan
has stopped running.
- Clean the air intake fil-
ter
- Remove it from the air
intake and the air out-
let.
- Wait for about 30 min-
utes to cool the unit
down and run again in
the room with the hu-
midity of above 35%.
Smell coming from the de-
humidifier when the first
use:
Need emptying frequently
when the first use:
e
The smell occurs because the
Zeolite absorbs odors from items
like cigarettes, cosmetics, and
building materials, and dis-
charged when the desiccant is
heated. It is normal, will not last
long and is not a sign of fault.
e As the room becomes dryer, the
dehumidifier collects less water.
SYMPTOM
Unit does
not work.
The device
does not de-
humidify.
The dehu-
midifier
works, but
reduces the
relative hu-
midity insuf-
ficiently /
there is little
water in the
water tank.
Dehumidifier
is blowing
out warm air.
CAUSE
- Power cut.
- The plug has been
plugged improperly.
- The full-tank indicator
is ON. Tank is full.
- The water tank is full.
- The water tank has not
been replaced correct-
ly
- The air filter is
clogged.
- The temperature in the
room where the dehu-
midifier is operating is
too low.
- The relative humidity in
the room where the
dehumidifier is operat-
ing is too low.
- The house is too large.
- There are too many
source of moisture.
Bathing, washing, dry-
ing clothes and cook-
ing all puts moisture
into the air. Calor gas
heating can add too
much moisture into the
air for a dehumidifier.
- The air filter is blocked
and the reduce air flow
is affecting perfor-
mance.
- The dried air is past
over a heating element
before it is blown into
the room as part of the
dehumidification
process.
SOLUTION
- Wait for power to be
supplied again.
- Plug in again.
- Remove the drain wa-
ter from the water
tank.
- Remove the water
from the water tank.
- Place the water tank
in the correct position.
- Clean the air filter.
- The machine does not
dehumidify below 1˚C,
it is highly unlikely at
that temperature that
there is any moisture
to remove anyway.
- The dehumidifier dries
down to the target rel-
ative humidity set and
then goes into fan on-
ly mode until the rela-
tive humidity goes
above the set point
again.
- Recommend to use a
dehumidifier with a
greater capacity.
- Recommend to use a
dehumidifier with a
greater capacity.
Consider using a dif-
ferent heat source to a
calor gas heater.
- Clean the air filter.
- This is normal, a de-
humidifier is not an air
cooler.
TD-Z110.qxd 14.5.22 16:25 ページ 3