1. Set the Weekly Timer

NOTE: The following programs are set at the factory in advance.

After setting the current time and a day of the week, press the “TIMER” button to enter the weekly timer setting

mode. The “TIMER” is shown on the display. When the “TIMER” button is pressed during setting of the weekly

timer, the “TIMER” sign is disappeared and the current clock time and a day of the week are shown on the

display.

NOTE: You cannot enter the weekly timer setting mode, while in operation at AUTO operation mode.

1) Select the program number

Press the “

▲MIN.” button or the “▼HOUR” button to select the program number.

The number of the program is 30. The unsetting program number is flashing on the display. In the case of the first

setting of the weekly timer, “P01” is shown on the display and will blink. When the unsetting program number is

shown on the display, all of a day of the week will also blink.

When pressing the “

▲MIN.” button, the sign will change as follows.

“P01”

➞ “P02” ➞ ··· ➞ “P29” ➞ “P30”

When pressing the “

▲MIN.” button at the position of “P30”, you can hear the beep sound and “P30” is not

changed any more.

When pressing the “

▼HOUR” button, the sign will change as follows.

“P30”

➞ “P29” ➞ ··· ➞ “P02” ➞ “P01”

When pressig the “

▼HOUR” button at the position of “P01”, you can hear the beep sound and “P01” is not

changed any more.

Basically, the only next program number of the biggest set program number is shown on the display and blinks.

All of 30 programs will not be shown on the display.

In case that the program is already set, the next number of the biggest setting program number is shown on the

display. If the program is set until “P30”, “P30” is shown on the display and will blink. Even though the program is

set until “P30”, if there is the unsetting program number, the smallest unsetting program number is shown on the

display.

Example:

In case that “P01” and “P02” programs are set and “P03” is not set, the display is indicated as follows.

“P01” – lighting

⇔ “P02” – lighting ⇔ “P03” – flashing 3

In case that “P01” and “P04” programs are set and “P02” and “P03” are not set, the display is indicated as

follows.

“P01” – lighting

⇔ “P02” – flashing 3 ⇔ “P03” – flashing 3 ⇔ “P04” – lighting ⇔ “P05” – flashing 3

Press the “SET” button to move to the next step (Set the timer).

The program number is eliminated by holding the “CLEAR” button continuously for 3 seconds.

Temp.

20˚C (68˚F)
16˚C (62˚F)
20˚C (68˚F)
16˚C (62˚F)
20˚C (68˚F)
16˚C (62˚F)
20˚C (68˚F)
16˚C (62˚F)

Day

“MON” “TUE” “WED” “THU” “FRI”
“MON” “TUE” “WED” “THU” “FRI”
“MON” “TUE” “WED” “THU” “FRI”
“MON” “TUE” “WED” “THU” “FRI”

“SUN” “SAT”
“SUN” “SAT”
“SUN” “SAT”
“SUN” “SAT”

Program #

P01
P02
P03
P04
P05
P06
P07
P08

Clock Time

6:00
8:30
17:00
23:00
7:00
10:00
16:00
23:00

11

FF_V30T_Type B_US.qxd 14.6.2 11:50 ページ 11