EMERGENCY MESSAGE

In the event that heater should extinguish itself, without any action or your part, you should
look to the digital indicator for any of the following messages.

MESSAGE

(Digital Indicator)

MESSAGE MEANING

e - 0
f - 0
e - 1
f - 1
e - 2
e - 5
e - 6
e - 7
e - 8
e - 9

Temperature within the heater too high.

Power interrupted. You can re-ignite the heater.

Thermostat is broken or disconnected. Contact your

dealer.

Faulty burner thermistor. Contact your dealer.

Primary flame rod is malfunctioning and /or dirty.

You have accidentaly activated your safety tip-over

switch. You should reset this device as described, press

the “OFF” button and restart your heater.
Burner flame has been extinguished during operation.

Check to see if air filter is clogged with dust. If so, clean

air filter.
Room temperature above 32

°C

Failure of blower motor.

Air filter dirty; or Fuel pump dirty.

Out of fuel. Refill removable fuel tank.

Too little ventilation. Ventilate better.

The heater has been in operation continuously for a

period of 65 hours and has turned itself off

automatically. Switch the heater back on.

-- :--

(& blinking FUEL-indicator)

-- :--

(& blinking VENT-indicator)