beautypg.com

Chapter 4 cu status indication by led indicators, Chapter 4, Cu status indication by led indicators – Denso CU-7011 User Manual

Page 13

background image

3

Chapter 4 CU Status Indication by

LED Indicators

According to the ON/OFF states of the POWER and DATA LED indicators, you may
check the machine status of the CU-7011 as listed below.

POWER

DATA

Machine status

OFF

OFF

Power off

ON

OFF

Power on

ON

ON

Communicating with the host

Flashing slowly*

1

ON

Updating the CU system program

Flashing slowly

Flashing*

2

Waiting for retry after occurrence of a
CU system program updating error

Flashing slowly

Flashing slowly

System program failure

Solution: Contact your nearest dealer.

Flashing quickly*

3

Flashing quickly

System program error

Solution: Restart the CU-7011. If this
error occurs frequently, contact your
nearest dealer.

*

1

At one-second intervals

*

2

At 100-ms intervals

*

3

At 50-ms intervals