Page 4

PRM-8 SET-UP

PRM-8 SET-UP OVERVIEW

(Refer to Figure 2.1)

The PRM-8 has three internal dip switches that may be used to
configure its operation for different system requirements. Before
installing the PRM-8, refer to the switch function description
below to determine the switch positions best suited to your
system requirements. Refer to page 10 for a typical control panel
configuration and its operation.

OXMOOR CORPORATION

MADE IN USA

PRM-8

COPYRIGHT 1994

PCB # 1300129

REVISION A

SW2

SW3

SW1

230

ON

1234

5678

ON

1234

5678

ON

1234

5678

SW6

POWER LED

SW 1

SW 3

SW 2

AC POWER TRANSFORMER

SW3 SET-UP PROCEDURE

(Refer to Figure 2.3)

SW3 allows individual channels to NOT receive the All
Page source. Those channels switched OFF will continue to
mute and ramp the program source during an All Page, but
will not receive the All Page source.

SW3

ON

1234

5678

1
2
3
4
5
6
7
8

PRM-8 Program Channels

Figure 2.3: Factory Set-Up for SW3

SW2

ON

1234

5678

1
2
4
8
16
32
64
128

PA-422 Address

Figure 2.2: Factory Set-Up for SW2

SW2 SET-UP PROCEDURE

(Refer to Figure 2.2)

Switch SW2 determines the PA-422 address. When the PA-
422 port is to be used, the PRM-8's PA-422 address should be
set to the same address as the controlling device. PA-422
requires that a device's address be between 1 and 250.

SW2:

Shipped from factory with
PA-422 set to address 2.

Figure 2.1: SW1, SW2 and SW3 Location on Printed Circuit Board

SW3:

Shipped from factory with all
channels set to receive the All
Page source (all channels ON).

1

* Off

= Not used, set to Off position

2

* Off

= Not used, set to Off position

3

Off

= Zone Page selection is NOT stored

* On

= Zone Page selection is stored

4

* Off

= Channel Select set for MAINTAINED closures

On

= Channel Select set for MOMENTARY closures

5

* Off

= Mic/Line input NOT used as All Page

On

= Mic/Line input used as All Page

6

Off

= Line input NOT used as All Page

* On

= Line input used as All Page

7

Off

= Mic/Line input NOT used as Zone Page

* On

= Mic/Line input used as Zone Page

8

* Off

= Line input NOT used as Zone Page

On

= Line input used as Zone Page

*

Indicates factory settings.

Note:

The Zone Page Clear function can be used only
if the Control Port is set for MOMENTARY
operation (#4 ON).

SW1:

Shipped from factory configured as shown.

Figure 2.0: Factory Set-Up for SW1

SW1

ON

1234

5678

CAUTION!

Hazardous voltages are present inside the chassis.

Before opening the case to gain access to the printed

circuit board, always remove the power from the unit by

disconnecting the AC power cord.

If changes are required:
1. Disconnect the AC power cord.
2. Remove the screws that secure the top cover and set the cover

aside.

3. Use the front panel Power LED and the AC Power

Transformer as reference points to locate SW1, SW2 and SW3
which are located on the component side of the PRM's printed
circuit board

.

SW1 SET-UP PROCEDURE

(Refer to Figure 2.0)

Switch SW1 determines if: A manual Zone Page Clear line is to
be used; The system is to store the Zone Page selections after a
zone page; The Channel Select is to operate with momentary or
maintained closures; The Page inputs are to be used as All Page,