beautypg.com

Prm-8 callouts, Page 2 – Oxmoor PRM-8 User Manual

Page 4

background image

PRM-8 CALLOUTS

Page 2

PRM-8 PAGE ROUTING MODULE

POWER

DUCK

LEVEL

FADE IN

FADE OUT

PAGE LEVEL

CH1

CH 2

CH 3

CH 4

CH 5

CH 6

CH 7

CH 8

0

-80

0

5

0

5

-80

0 -80

0 -80

0 -80

0 -80

0 -80

0 -80

0 -80

0

1

2

3

4

5

10. MIC/LINE LEVEL

- Accessed through the back panel with a

small flat-blade screwdriver, adjusts the MIC/LINE input
for varying input signal levels.

11. LINE IN

- Page input, terminal block connections with

mating connector, electronically balanced input, accepts
balanced or unbalanced signals from line-level devices.
Normal input level is +4 dBu with a maximum input level
of +24 dBu.

12. LINE LEVEL

- Accessed through the back panel with a small

flat-blade screwdriver, adjusts the LINE input for varying
input signal levels.

13. CONTROL PORT

- Female, 25-pin, standard D-sub connector.

Provides connections for external switching of: Zones for
zone paging, Zone Page Enable, All Page Enable, and Zone
Page Clear. Also provides tally connections for all control
functions.

14. PA-422 IN

- Male, 9-pin D-sub connector. This port

connects to the PA-422 OUT of the MCS-MCP Master
Control Panel, an MCS-IB Interface Box or other PA-422
control devices.

15. PA-422 OUT

- Female, 9-pin D-sub connector. It is used to

carry the PA-422 data to the next PA-422 device.

16. FUSE HOLDER

- Replace only with approved type of fuse

in a rating appropriate to the mains voltage, as indicated
on back panel. (See SPECIFICATIONS).

17. POWER CONNECTOR

- Standard IEC 3-pin connector for

AC power cord. Use only with grounded (3-wire) outlets.
Cord sets are available for all world connection
standards.

18. CHASSIS GROUND POST

- A screw with a star washer

enables the installer to secure a ground wire to the
chassis.

Figure 1.0: Front Panel View

1.

POWER STATUS LED

- Indicator for AC Power On.

2.

DUCK LEVEL

- Duck level control pot, accessed through the

front panel with a small flat-blade screwdriver, adjusts the
level to which program material is attenuated during a
page. Range is from 0 (no ducking) to -80 dB.

3.

FADE IN

- Accessed through the front panel with a small

flat-blade screwdriver, sets the time required, during a
page, for the program material to be attenuated to the
level established by the DUCK LEVEL control.

4.

FADE OUT

- Accessed through the front panel with a small

flat-blade screwdriver, sets the time required for the
program material to return to its prior level upon
cessation of a page.

5.

PAGE LEVEL

- Accessed through the front panel with a

small flat-blade screwdriver, these attenuators adjust
page level, from 0 to -80 dB, in each zone individually.

6.

PROGRAM OUTPUTS

- Audio outputs, terminal block

connections with mating connector, electronically
balanced, accommodate balanced or unbalanced lines.
Recommended load impedance is 600 ohms or greater.
Maximum output level is +24 dBu.

7.

PROGRAM INPUTS

- Audio inputs, terminal block

connections with mating connector, electronically balanced,
accept balanced or unbalanced signals from line-level
devices. Normal input level is +4 dBu with a maximum input
level of +24 dBu.

8.

MIC, LINE

- Switch configures the MIC/LINE input to

accept either a microphone-level or a line-level source.

9.

MIC/LINE

- Page input, XLR-F type, Pin 2 positive,

electronically balanced, accepts balanced or unbalanced
signals. Normal input level is dependent on the MIC,
LINE switch setting. Microphone input level is -50 dBu
with a maximum input level of -20 dBu. Line input level
is +4 dBu with a maximum input level of +24 dBu.

8

7

6

5

4

3

2

1

8

7

6

5

4

3

2

1

PROGRAM OUTPUTS

PROGRAM INPUTS

PA-422 IN

CHASSIS

PA-422 OUT

CONTROL PORT

PAGE INPUTS

+

S

LINE

LEVEL

LINE

MIC/LINE

LEVEL

MIC/LINE

+

S

OXMOOR

MADE IN USA BY

OXMOOR CORPORATION

BIRMINGHAM, ALABAMA

SERIAL #

LINE

MIC

POWER

FUSE

PUSH

13

Figure 1.1: Rear Panel View

14

16

8

9

10

15

17

18

6

7

12

11