4.3 Ground connection

For enhanced safety to reduce the risks of electrical shock and physical damage, caused by

lightning and other power surges, as well as a connection to the surge suppresion devices in the

product, a screw terminal is provided on the Standalone cabinets (Fig. 4.5). It is highly

recommended that the Standalone unit have good ground connections to the buildings ground in

accordance with the local codes.

Fig. 4.5 Standalone unit earth ground terminal location

(5) Operational Guides

5.1 FT080CF Series Transmitter

LED Indicators

Indicator

Color

Description

PWR

Red

Lit when power is supplied to the Transmitter.

OL

Yellow

Lit when optical signal from receiver to transmitter is active.*

CC 1-8

IN

Red

Blinks when input contact closure is available at Tx.

OUT

Green

N/A

AL

Blue

N/A

*

For products with uni-directional signal transmission, the OL LED on the Tx is not lit because optical signal from the Rx to the Tx is

always inactive.

Signal Ports

OPT - ST (or FC) Optical Connector for fiber cable connection.

CC 1-8 - 5-pin Screw Terminal Block for contact closure signal.