2. INSTALLATION
INSTALLATION
2.1.
Power Supply
2.2.
Connections
2
The digital dynamics processor d02 is a device under the safety
category Schutzklasse 1 in keeping with the VDE 0804 standards and
may only used with power supply installations built according to
regulations.
Check the voltage details printed at the rear panel are the same as
your local mains electricity supply.
All input and output connectors of the digital dynamics processor d02
are arranged in functional groups on the rear panel.
LEFT
RIGHT
LEVEL
ANALOG OUTPUT
ANALOG INPUT
LEFT
RIGHT
LEVEL
OUT
AES/EBU
S/PDIF
OPTICAL
OUT
IN
IN
model d02
230 V
50 Hz
200 mA
Nr
REMOTE
EXT SYNC
16
20
BIT
DIG OUT
24
CON
STATUS
PRO
POWER INPUT
IEC mains input connector 100-240V, 50/60 Hz with integrated fuse
REMOTE
for optional serial remote interface RS-232 input and output
connector:
15pin SUB-D, male
DIGITAL INPUTS AND OUTPUTS
AES/EBU
input and output for AES/EBU standard format
input:
XLR female panel jack
1- open, 2-3 signal, balanced, max. 5 Vpp
output:
XLR male panel jack
1- open, 2-3 signal, balanced, max. 5 Vpp
S/PDIF
digital format for semi-professional use
When a signal is present at the AES input at the same time it has
preference over SP/DIF
Input and output : RCA socket
OPTICAL
Optical interface for digital audio signals, (do not use input together with
SP/DIF
input)
Input and output : TOSLINK
EXT SYNC
Word clock input for external synchronisation
Input and output: BNC, (TTL-level)
2-1