Since this type of module has an electronic output routing facility, great care must be taken when installing
or exchanging a module!

SW1
1: BUS-EN

ON

the output configuration will be taken from the NV (non volatile) memory

after power up.

OFF

will set all bus outputs to Tri-State-Mode (inactive). Now you can use the

frame controller to configure the board. This configuration will automatically

be stored into the NV memory. To enable the configuration for the next

power up you must pull out the module and set BUS-EN=ON again.

Important note! If an unknown output bus configuration is stored, it can cause a conflict with
other modules in the frame. If you are not sure about the output bus configuration you must turn
BUS-EN=OFF before inserting such a module into a system that is On Air.


2: Not used

OFF

3: Not used

OFF

4: ID +16

ON

CAN address range is extended by +16, ranges from 0x10 to 0x1F (16 – 31)

OFF

CAN address ranges from 0x0 to 0xF (0 – 15)


SW2
CAN
rotary encoder

0 – F
sets the CAN bus address. Each module within a frame must be assigned a
unique CAN bus address for proper communication with other modules of
the frame (see also ID +16 above).


Important note! This address also sets the position of the module graphic when you control the
frame via the web GUI by a C8702 frame controller.

Addresses from “0” to “7” will place the module graphic into the third row
(first row shows the frame controller and sync modules, second row is
empty). Addresses “8” to “F” will place it into the fourth row and so on.
I.e. address “0” will place it in upper left position of row 3, while “1F” will place
it in lower right position of row 6.

SW3
INIT

pressing the INIT button during power up will initialize the module parameters
to factory default values.