There are three additional options for the Relay Outstation
that are independent of the Relay’s mode settings.
Two of these options control the behaviour of the Call lamp on
the Master Station. The third option, All lamps enabled
blanks all lamps on the Relay Outstation. This is useful when
the Relay Outstation needs to hide from public view.
When the lamps are disabled, pressing the Enable button on
the Relay Outstation will momentarily light the Outstation’s
lamps so that its operation can be monitored or its mode
changed.
More Relay Options
The Cue Light mode is one of five possible modes that a
Relay can be assigned to. There are seven additional
options for this mode which only come into effect when the
Relay is assigned to the Cue Light mode.
Select a Cue Light mode option to be edited using the
buttons
The green buttons indicate the status of this option for
each of the 16 channels. When a green button is illuminated,
the option for that channel is active/selected.
Toggle all 16 channels at once by using the Edit all 16 ch
button
Cue Light Mode
S/by Flash on Master
S/by Flash on Outstation
S/by latches
Go times out
Go flashes
Go latches
Go & S/by interlocked
Factory
Default
Flashes
Flashes
Latches
Times out
Flashes
Latches
Interlocked
Steady
Steady
Momentary
Stays on
Steady
Momentary
Independent
User Selectable
Option
Options
Cue Light Mode options for the Relay (QLRi2) Outstation
When the Cue Light mode is selected, the following 7
options are available. All options can be programmed
individually for each channel.
Call lamp Flashes
All lamps enabled
Call lamps enabled
Factory
Default
Enabled
Flashes
Enabled
Call
off
Steady
Off
lamp
User Selectable
Option
Options
More options available for all 5 modes
There are three more Relay options:
2
3
Relay options
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Power
5 modes for each Relay
Options for Relay’s Cue Light Mode
More Relay Options
1
2
3
Master Station Configuration Editor
2
3
5
6
44.
(continued)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Power
Theatre Cue Light
Master QLM16i2 Mk4
www.interspaceind.com
Innovation by:-
Built By:-
4
Exit
Relay & Sensor.
Page 2
Select
page
Save
Open
Edit all
16 ch.
Installer
defaults
User 1
User 2
User 3
User 4
Show
Time
Factory
default red
Factory
default yel
S/by flash
on Master
S/by flash
on Outstn
S/by
latches
Go
times out
Go
flashes
Go
latches
Go & S/by
interlocked
Call lamp
enabled
Call lamp
flashes
All lamps
enabled
A: Latch
B: Latch
A: Mom
B: Latch
A: Latch
B: Mom
Cue Light
Mode
A: Mom
B: Mom
Safe when
open
Unsafe
flashes
No
EOL
All lamps
enabled
Sensor
Options
Relay
Options
Edit
Channel
5
6