Dmx connection, Signal wiring, Dmx junction box wiring – ILUMINARC Ilumipod™ Inground Tri-3 IP User Manual
Page 5: Dmx cable table, Ilumipod inground tri-3 ip optic 25 rgb qrg
Ilumipod Inground Tri-3 IP Optic 25 RGB QRG
5
DMX
Connection
You can connect the bare-ended IP67 rated signal cable from this product
to two IP67 rated signal connectors (DMX in and DMX Out) or use an
IP67 rated junction box. If using an IP67 rated junction box, make sure to
use IP67 rated conduit.
Signal Wiring To provide a signal for this product, you can connect the bare-ended IP67
rated signal cable from the product to two IP67 rated signal connectors
(DMX in and DMX out) or use an IP67 rated junction box. If using an IP67
rated junction box, make sure to use IP67 rates conduit.
The signal cable must match or exceed the electrical characteristics of
the Belden® 9841 cable for EIA RS-485 applications. You can also use
CAT 5, CAT 5e, or CAT 6.
DMX Junction
Box Wiring
DMX
Cable Table
Connection
DMX In
DMX Out
IP67 Pin
Ground
Shield
Shield
1
Data -
Black
Green
2
Data +
White
Red
3