Ac power, Junction box, Power wiring – ILUMINARC Ilumipod™ Inground Tri-12 IP User Manual
Page 5: Power cable table, Signal wiring, Very important, Ilumipod inground tri-12 ip
Ilumipod Inground Tri-12 IP
5
AC Power
This product has an auto-ranging power supply that can work with an input
voltage range of 100~240 VAC, 50/60 Hz.
Junction
Box
This fixture has an IP67 rated junction box where the power and signal
cables come into the unit. The cables access the junction box through
individual (signal and power) IP67 rated stainless steel gland nuts.
Make sure that the junction seal is clean before placing the cover back on.
In addition, tighten the gland nuts and the junction cover to prevent water
from entering the junction box and cause a short.
The figure below shows the connections in the junction box.
Power
Wiring
To provide AC power to this fixture, you must run a single STJW rated, 3-
conductor cable (AWG18/3, 6~8 mm external diameter) from the power
distribution box into the installation sleeve and the fixture’s junction box.
Make sure to strip the end of the AC
power cable that will connect to the
junction box as indicated in the figure
on the right.
Power Cable Table
Connection
Wire (US)
Wire (Europe)
AC Live
Black
Brown
AC Neutral
White
Blue
AC Ground
Green/Yellow
Green/Yellow
Signal
Wiring
To provide signal to this fixture, you must run a single, IP67 rated DMX
signal cable (shielded, 2-conductor, AWG24/2, 6.5 mm external diameter)
from the signal distribution box into the installation sleeve and the fixture’s
junction box. The signal cable must match or exceed the electrical
characteristics of the Belden® 9841 cable for EIA RS-485 applications.
VERY IMPORTANT
Make sure to use power and signal cables with the indicated outer diameters
to ensure that the corresponding gland nut makes full contact with the
cable’s external insulation. This is required to ensure watertightness once
fully adjusted.