Installation

Ilumipod 18g2 IP Optic RGB User Manual (Rev. 2)

7


Always connect
the Ilumipod
18g2 IP Optic

RGB to a protected circuit
with an appropriate
electrical ground to avoid
the risk of electrocution or
fire.

Never connect
the Ilumipod 18g2
IP Optic RGB to a

rheostat (variable resistor)
or dimmer circuit, even if
the rheostat or dimmer
channel serves only as a
0% to 100% switch.

Make sure to
connect the
Ilumipod 18g2 IP

Optic RGB to a power line
with the proper voltage
and frequency, as per the
specifications in this
manual or on the
product’s sticker.

AC Power

The Ilumipod 18g2 IP Optic RGB has an auto-ranging power supply that works with an input
voltage range of 100~240 VAC, 50/60 Hz.

Make sure that you are connecting this product to the proper voltage, as per the specifications in
this User Manual or on the product’s sticker.

Power Consumption

To determine the power requirements for the Ilumipod 18g2 IP Optic RGB, refer to
the label affixed to the side of the product. You may also refer to the

Technical

Specifications

.

The listed current rating indicates the maximum current draw during normal operation.

AC Plug

The Ilumipod 18g2 IP Optic RGB comes with a bare-ended power input cord for
hardwire installation. Use the table and the illustration below to wire a plug.

Connection

Wire (U.S.)

Screw Color (U.S.) Wire (Europe)

IP67 Pin

AC Live

Black

Yellow or Brass

Brown

1

AC Neutral

White

Silver or Gray

Blue

2

AC Ground

Green/Yellow Green

Green/Yellow

3



The listed
current rating
indicates the
maximum

current draw during
normal operation.

If you choose to
bury the power or
signal distribution

boxes, make sure that
they are IP67-rated or
greater.




Power Wiring

You can connect the bare-ended, IP67-rated AC power cable from the product to an
IP67-rated power connector or IP67-rated junction box.