Holland Electronics ST-5128S User Manual
Page 4

3
SPECIFICATIONS
Input Impedance 75 Ohms
Input Frequency
46 – 860 MHz
Frequency Stability
<30 ppm
Frequency
Accuracy 15
KHz
Min. Tuning Increment
10 KHz
I.F. Bandwidth
230 +/- 50 KHz
Input
Range
-40
to
+60
dBmV
Frequency Mode Tuning Increments 10 KHz
Amplitude Measurement Accuracy
±1 dB @ 24°C ±1.5 dB (-10° to +50°C)
CHANNELTYPE
NTSC
(6
MHz)
SPECTRUM ANALYZER MODE
Single Channel Width
6 MHz / 12 MHz
Resolution
100
/
150
KHz
Display Dynamic Range
40 - 100 dB
Full Spectrum Scan
All Visual Carriers
POWER LEVEL TESTING
Range -40 to +60 dBmV
Accuracy +/- 1.5bDmV
Resolution 0.1 dBmV
A.C. VOLTAGE TESTING
Range +20 to 100 vac, alarms above +100v
Accuracy +/- 1.0v
Resolution 0.1v
DISPLAY TYPE
Digital Graphic LCD
Indicates Channel or Frequency, signal
level in dBmV or dBuV, plots graphics
LCD Controls
ContrastLevel, Back Lighting
FEATURES
Input Connector
Replaceable High Return Loss F Type
Spectrum Viewing
Single channel or Full Spectrum
Audio
Adjustable
Volume
AC Input
110 V / 60 Hz
Battery use
8 Hours Minimum / Charge
Auto Power Shut-Off
Size in. (mm)
4.3”(110) x 10”(248) x 2.6” (65)
Weight
2
Lbs
(.9
Kg)