Lsm fse/pse efa – Future Automation LSM-FSE User Manual
Page 18

PROTOCOL
ACTION
fa_in Carriage Return (Enter )
Device IN
fa_out Carriage Return (Enter )
Device OUT (90 Degrees)
fa_preset A-F Carriage Return (Enter )
Device to PRESET or A-F memory positions
fa_stop Carriage Return (Enter )
STOPS the device at any position
fa_home Carriage Return (Enter )
Lift UP facing forward (Default Position)
In
st
al
la
ti
o
n
:
R
S
23
2
C
on
tr
ol
Page 17 of 20 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSM FSE/PSE EFA -
Lift System with FSE or PSE Mount & Electric Flap Actuator
Connection Locations
Mains Voltage Input
IR LED
IR Input Jack
RS232
Contact Closure
Emergency Stop Connector
SLQV
RS232
- Use an RJ25 connector
in the socket marked
RS232 on the control box
to operate using RS232
Details
Baud rate: 9600
Stop bit:
1
Parity:
None
Databits:
8
Pin 1: RX
Pin 6 : TX
Pin 3 & 4: GROUND
Pin 2: TX
Pin 3: RX
Pin 5: GROUND
IMPORTANT
Ensure protocol is entered exactly as written, including Carriage Return (Enter / ASCII 13).
RJ25
9 PIN D
PIN 1: RX
TO
PIN 2: TX
PIN 6: TX
TO
PIN 3: RX
PIN 3: GROUND
TO
PIN 5: GROUND
PIN 4: GROUND
TO
PIN 5: GROUND