Advanced option menu – DynaScan 46″ Video Wall Super Narrow Bezel LCD DS46LX2 User Manual
Page 30
21
EXIT
MENU
:SEL
+-:ADJ
:RETURN
:EXIT MENU
SCREEN SAVER
COOLING FAN
BRIGHTNESS
MOTION
AUTO
OFF
OFF
• {
COOLING FAN} - Select {ON} to turn on the cooling fan
all the time. Select {
AUTO} to turn on/off the cooling fan
according to the display’s temperature.
NOTES:
• The default {
AUTO} option will start running the cooling
fan if the temperature of
65°C (152°F) is reached, and
will keep running for
30 minutes after cooling down to the
temperature of
62°C (144°F).
• A temperature-warning message will be shown on the
screen once the temperature reaches
79°C. All key
function except [
Power] key will then be disabled.
• {
BRIGHTNESS} - Select {ON} and the brightness of
the image will be reduced to an appropriate level, and
the Brightness setting in the Picture menu will become
unavailable.
• {
MOTION} - Select the time interval ({10 ~ 900} Seconds /
{
OFF}) for the display to slightly expand the image size and
shift the position of pixels in four directions (up, down, left, or
right).
SIDE BORDER COLOR
Adjust the brightness of the black areas displayed on both sides
of 4:3 images.
CONFIGURATION3 RESET
Reset all settings in the
CONFIGURATION3 menu to factory
preset values.
4.2.8. ADVANCED OPTION menu
PIP
1
2
3
SET
EXIT
MENU
:SEL
:NEXT
INPUT CHANGE
TERMINAL SETTING
SCAN CONVERSION
COLOR SYSTEM
SCAN MODE
SERIAL CONTROL
LAN SETTING
ADVANCED OPTION RESET
FACTORY RESET
ADVANCED OPTION
:RETURN
:EXIT MENU
NORMAL
LAN
INPUT CHANGE
Select the time for input switching as {
NORMAL} or {QUICK}.
NOTE: The selection {
QUICK} may cause a slight noise.
TERMINAL SETTING
Select the mode to display the HDMI or DVI signal according to
their signal format depending on their source device.
• {
DVI MODE}: Used for DVI-D signal.
• Select {
DVI-PC} when the source device is a PC.
• Select {
DVI-HD} when the source device is a video
device.
• {
HDMI SIGNAL}: Used for HDMI signal.
• Select {
LIMITED} when displaying the signal that uses
16 to 235 levels of 256 levels for each R, G, and B.
• Select {
FULL} when displaying the signal that uses all
256 levels (from level 0 to 255).
PIP
1
2
3
EXIT
MENU
:SEL
+-:ADJ
DVI-MODE
HDMI SIGNAL
TERMINAL SETTING
:RETURN
:EXIT MENU
DVI-PC
FULL
SCAN CONVERSION
Choose to enable or disable the IP (Interlace to Progressive)
conversion function.
• {
PROGRESSIVE} - Enable the IP conversion function
(recommended). Once enabled, the interlace input signal will
be converted to progressive format for better display quality.
• {
INTERLACE} - Disable the IP function. This mode is
suitable for displaying motion pictures, but it increases the
chance of image retention.
COLOR SYSTEM
Selects the Color System depends on your input video format.
The options are: {
AUTO} / {NTSC} / {PAL} / {SECAM} /
{
4.43NTSC} / {PAL-60}.
NOTE: This item is functional for
S-VIDEO or VIDEO input
only.
SCAN MODE
Change the display area of the image.
• {
OVERSCAN} - Display about 95% of the original size of the
image. The rest of the areas surrounding the image will be
cut off.
• {
UNDERSCAN} - Display the image in its original size.
NOTE: This item is functional for
HDMI-Video timing input
only.
SERIAL CONTROL
Select the nectwork control port.
The options are: {
RS-232C} / {LAN}.
NOTE: If {
LAN} is selected, then {RS-232C} will not be
activated, even if a cable is attached, and vice versa.
LAN SETTING
Assign {
IP ADDRESS}, {SUBNET MASK}, and {DEFAULT
GATEWAY} for the display.
DS32CR \DS42CR \DS46CR \DS46LX Series