Troubleshooting

Error Codes

Problem

Cause

Action

Unit will not

turn on

(no power)

Yellow or red wire not connected or
incorrect voltage

Check connections for proper
voltage (11~16VDC)

Black wire not connected

Check connection to ground

Fuse blown

Replace fuse

Unit has power

(but no sound)

Speaker wires not connected

Check connections at speakers

One or more speaker wires touching
each other or touching chassis
ground

Insulate all bare speaker wires
from each other and chassis
ground

Unit blows

fuses

Yellow or red wire touching chassis
ground

Check for pinched wire

Speaker wires touching chassis
ground

Check for pinched wire

Incorrect fuse rating

Use fuse with correct rating

Excessive

skipping

Unit is not mounted correctly or
backstrap is not secure

Check mounting sleeve and
backstrap support

Physical defect in media
(CD, CD-R or CD-RW)

Check media for scratches

Error Code

Cause

Action

ER01 appears on display

High internal temperature

Turn unit off for 1 hour

ER02 appears on display

Load/Eject operation error

Press eject or RESET

ER03 appears on display

Focus adjustment error

Clean or replace media

ER04 appears on display

Tracking auto adjustment error

Clean or replace media

ER06 appears on display

Sled operation error

Press eject or RESET

ER07 appears on display

Focus search operation error

Press eject or RESET

ER08 appears on display

CLV (PLL) operation error

Press eject or RESET

ER09 appears on display

TOC data read error

Clean or replace media