Troubleshooting
Error Codes
Problem
Cause
Action
Unit will not
turn on
(no power)
Yellow or red wire not connected or
incorrect voltage
Check connections for proper
voltage (11~16VDC)
Black wire not connected
Check connection to ground
Fuse blown
Replace fuse
Unit has power
(but no sound)
Speaker wires not connected
Check connections at speakers
One or more speaker wires touching
each other or touching chassis
ground
Insulate all bare speaker wires
from each other and chassis
ground
Unit blows
fuses
Yellow or red wire touching chassis
ground
Check for pinched wire
Speaker wires touching chassis
ground
Check for pinched wire
Incorrect fuse rating
Use fuse with correct rating
Excessive
skipping
Unit is not mounted correctly or
backstrap is not secure
Check mounting sleeve and
backstrap support
Physical defect in media
(CD, CD-R or CD-RW)
Check media for scratches
Error Code
Cause
Action
ER01 appears on display
High internal temperature
Turn unit off for 1 hour
ER02 appears on display
Load/Eject operation error
Press eject or RESET
ER03 appears on display
Focus adjustment error
Clean or replace media
ER04 appears on display
Tracking auto adjustment error
Clean or replace media
ER06 appears on display
Sled operation error
Press eject or RESET
ER07 appears on display
Focus search operation error
Press eject or RESET
ER08 appears on display
CLV (PLL) operation error
Press eject or RESET
ER09 appears on display
TOC data read error
Clean or replace media