9 — ENG

5.

Some pumps are shipped from the

factory

with a red shipping plug. Refer

to page 16 and 17 to identify your pump.
The Annovi Reverberi pump can also be
identified by its name printed on top of

the pump. The shipping plug prevents any oil from
leaking out of the pump in shipping. Attached to the
shipping plug is a plastic bag which contains the
new oil plug. The shipping plug must be removed
and the new oil plug installed before the pressure
washer is operated-see illustration C. To remove
the shipping plug, turn counterclockwise and dis-
card. Remove the new oil plug from the plastic bag
and insert into the pump. Tighten securely.

Illustration C

OPERATING PROCEDURES

Figure 1

Figure 2

Twist Connect

Figure 3

Quick Connect

OR

Add Gas

OPERA

TION

ATTENTION: Become familiar with the operating procedures before starting your unit.

Start-Up

1.

Add fresh high quality unleaded gasoline—Figure
1.

2.

Check engine oil level. See Engine Operator's
Manual for correct amount and type.

NOTE: Some engines are equipped with a low oil
sensor and the correct amount of oil must be
added or the engine will not start.

3.

Check pump oil level (if applicable–See Mainte-
nance Section.)

4.

Connect high pressure hose to pump outlet —
Figure 2 for threaded hoses. Figure 3 for hose with
quick connects.

Never pull water supply hose to move
pressure washer. This could damage hose
and/or pump inlet.