beautypg.com

Operation, Controller settings, Operation 2.3.1. controller settings – d&b 10S User Manual

Page 7

background image

NL4 connection with cover plate
The two NL4 connector sockets of the cabinet's connector panel

are located in a recess to allow the use of the cover plate

[1]

together with NL4 cable connectors, as shown in the graphic

opposite.

Note: Neutrik NL4FC type connectors must be used for this

option.

The cover plate is equipped with two knockout openings to allow

daisy chaining of the loudspeaker.

To use the NL4 connection, proceed in the same manner as

described above in the section entitled Þ "Fixed cable connection"

on page 6.

2.3. Operation

NOTICE!

Only operate d&b loudspeakers with a correctly configured d&b

amplifier, otherwise there is a risk of damaging the loudspeaker

components.

Operation with D6 or D12
Select the controller setup 10S/A for 10S loudspeakers.

Select the controller setup 10S/A-D for 10S-D loudspeakers.

Within the D12 amplifier they are available in "Dual Channel" or

"Mix TOP/SUB" mode. For combinations with active subwoofers

fed by a single 4-wire cable "Mix TOP/SUB" mode must be

selected.

Up to a total of three 10S or 10S-D loudspeakers can be driven by

each channel of the D6 or D12 amplifiers.

2.3.1. Controller settings
For acoustic adjustment the functions CUT, HFA and CPL can be

selected.

CUT circuit
Set to CUT, the cabinet low frequency level is reduced. The

cabinets are now configured for use with d&b active subwoofers.

Fig. 5: NL4 cable connection with cover plate [1]

d&b 10S/10S-D Manual (1.1 EN)

7

This manual is related to the following products: