Specifications, General, Converter pec25 – CUE Power Express User Manual
Page 17: Dimmer ped108, Dimmer ped202
4. Specifications
4.1. General
EMI radiation .......................................According to EN55014 and EN55011 standard
Power supply .......................................230 VAC (version 230V) or 110 VAC (version 110V), 50/60 Hz
Communication....................................PEbus (RS-485)
Enclosure.............................................Plastic
Storage temperature............................-20 to 90 °C
4.2. Converter PEC25 .............................................................................
Power supply .......................................From PEbus or external 7.5 - 30 VDC, 100 mA
Baud rate .............................................19 200 bits/sec
Connectors ..........................................2x RJ-11-4 for PEbus
Sub-D, 9-pin, female for RS-232
Terminals for RS-232
Weight..................................................0.1 kg
Dimensions ..........................................36 x 90 x 58 mm (2 modules 17.5 mm)
Operating ambient temperature ..........0 to 60 °C
Supplied accessories...........................PEbus Cable CA0130
4.3. Dimmer PED108 ..............................................................................
Regulated output .................................1x 8 A
Way of regulation.................................Leading - edge phase control
Over-current protection........................Quick-brake fuse 5 x 20 mm, F8A
Cooling system ....................................Passive aluminum heat sink
Insulation strength ...............................2.5 kV between power and control circuits
Connectors ..........................................2x RJ-11-4 for PEbus
Terminals up to 1.5 mm
2
for inputs and outputs
Weight..................................................0.75 kg
Dimensions ..........................................106 x 90 x 58 mm (6 modules 17.5 mm)
Operating ambient temperature ..........0 to 40 °C
Supplied accessories...........................PEbus Cable CA0130
4.4. Dimmer PED202 ..............................................................................
Regulated outputs ...............................2x 2.7 A per channel (4 A total)
Way of regulation.................................Leading - edge phase control
Over-current protection........................Quick-brake fuse 5 x 20 mm, F4A
Cooling system ....................................Passive aluminum heat sink
Insulation strength ...............................2.5 kV between power and control circuits
Connectors ..........................................2x RJ-11-4 for PEbus
Terminals up to 1.5 mm
2
for inputs and outputs
Weight..................................................0.5 kg
Dimensions ..........................................106 x 90 x 58 mm (6 modules 17.5 mm)
Operating ambient temperature ..........0 to 40 °C
Supplied accessories...........................PEbus Cable CA0130
User Manual Power Express
www.cue.cz
Page 17 of 24