CUE Wireless IR Control Panels User Manual
Page 16
User Manual Wireless IR Control Panels
www.cuesystem.com
Page 16 of 26
The address of the receiver can be set up by the Address Switch - see picture above. BUTTON_ID
sent by irCUE Receiver 485 to the control unit is a BUTTON_ID sent by IR wireless control panel with
an added OFFSET value. Button ID and OFFSET value are calculated according formulas below.
BUTTON_ID (irCUE Receiver 485) = Offset + BUTTON_ID (IR wireless control panel)
Offset = 32 * ADDRESS
ADDRESS is binary coded by DIP switch in the range 0 to 255.
ON
1
7
6
5
4
3
2
8
SW1 – ADDRESS bit 0
SW2 – ADDRESS bit 1
SW3 – ADDRESS bit 2
SW 4 – ADDRESS bit 3
SW 5 – ADDRESS bit 4
SW 6 – ADDRESS bit 5
SW 7 – ADDRESS bit 6
SW 8 – ADDRESS bit 7
ADDRESS of irCUE Receiver 485
OFFSET
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
0
0
OFF OFF OFF OFF OFF OFF OFF OFF
1
32 ON
OFF OFF OFF OFF OFF OFF OFF
2
64
OFF
ON
OFF OFF OFF OFF OFF OFF
3
96 ON
ON
OFF OFF OFF OFF OFF OFF
...
255
8