Connecting – CUE Wireless IR Control Panels User Manual
Page 12

User Manual Wireless IR Control Panels
www.cuesystem.com
Page 12 of 26
7.1.2. Connecting
The irCUE Receiver can be connected to
• Assistant
or
Assistant-S
using input marked IR-REC
• irCUE Receiver 485 - see connection example in the following chapter.
Up to (10) receivers can be connected in parallel. Connection example is described on the pictures
below.
Assistant or Assistant-S
IN
E
IR-REC
S9 / CUEring
OUT RS-485
G
CONSOLLE
1
3
2
Pin 3: IR +12 V
Pin 2: Input (data)
Pin 1: Ground
The terminal location and pin connection of the irCUE Receiver is described below. Both terminals on
irCUE Receiver are connected in parallel.
Signal
Name
irCUE Receiver
Terminals
Assistant
IR-REC
Assistant
IR-REC
Ground G
4b 8
Data D 5b
9
+12 V
+
6b
10
+12 V
Data
Ground
+12 V
Data
Ground