beautypg.com

Connecting – CUE Wireless IR Control Panels User Manual

Page 12

background image

User Manual Wireless IR Control Panels

www.cuesystem.com

Page 12 of 26

7.1.2. Connecting

The irCUE Receiver can be connected to

• Assistant

or

Assistant-S

using input marked IR-REC

• irCUE Receiver 485 - see connection example in the following chapter.


Up to (10) receivers can be connected in parallel. Connection example is described on the pictures
below.

Assistant or Assistant-S

IN

E

IR-REC

S9 / CUEring

OUT RS-485

G

CONSOLLE

1

3

2

Pin 3: IR +12 V

Pin 2: Input (data)

Pin 1: Ground

The terminal location and pin connection of the irCUE Receiver is described below. Both terminals on
irCUE Receiver are connected in parallel.

Signal

Name

irCUE Receiver

Terminals

Assistant

IR-REC

Assistant

IR-REC

Ground G

4b 8

Data D 5b

9

+12 V

+

6b

10

+12 V

Data

Ground

+12 V

Data

Ground