ratings & type Descriptions

Inverter Series

Version

J1000

J

1st

A

Specification

Coating Specification and Protection

Japanese spec.

A

Standard

A

European spec.

C

Moisture (humidity)/Dust-proof

M

USA spec.

U

Oil-proof

N

Vibration-proof

S

Input Voltage

Single-phase 230 VAC

B

Type

Three-phase 200 VAC

2

Fin

Filter

Protection level

Three-phase 400 VAC

4

Standard

No

IP20 without top cover

B

Standard

No

NEMA1(IP20)

F

Customer Specification

Standard

A

CIMR-

J

C

B

A

0001

B

A

A

Voltage class

400 V

Inverter

Model

Three Phase Inverter CIMR-JC4A

0001

0002

0004

0005

0007

0009

0011

Inverter

output

Motor output kW at normal duty *

1

0.4

0.75

1.5

2.2

3.0

3.7

5.5

Motor output kW at heavy duty *

1

0.2

0.4

0.75

1.5

2.2

3.0

3.7

rated output current at normal duty*

2

[A]

1.2

2.1

4.1

5.4

6.9

8.8

11.1

rated output current at heavy duty*

3

[A]

1.2

1.8

3.4

4.8

5.5

7.2

9.2

Overload

120% for 60 sec at normal duty, 150% for 60 sec at heavy duty

from inverter rated output current

Rated output power*

4

at normal duty*

2

[kVA]

0.9

1.6

3.1

4.1

5.3

6.7

8.5

Rated output power*

4

at heavy duty*

3

[kVA]

0.9

1.4

2.6

3.7

4.2

5.5

7.0

Max. output voltage

Three-phase 380 to 480 V (proportional to input voltage)

Max. output frequency

400 Hz

Inverter

input

Rated input voltage

Three-phase 380 to 480 V +10%/-15%

Rated input frequency

50/60 Hz +/-5%

*

1

The motor capacity (kW) refers to a YASKAWA 4-pole, 60 Hz, 400 V motor. The rated output current of the drive output amps should be equal to or greater than the motor rated current.

*

2

This value assumes a carrier frequency of 2 kHz to Swing PWM. Increasing the carrier frequency requires a reduction in current.

*

3

This value assumes a carrier frequency of 8 kHz. Increasing the carrier frequency requires a reduction in current.

*

4

Rated output capacity is calculated with a rated output voltage of 440 V.

*

1

Drives with a single-phase power supply input have three-phase output. Single-phase motors cannot be used.

*

2

The motor capacity (kW) refers to a YASKAWA 4-pole, 60 Hz, 200 V motor. The rated output current of the drive output amps should be equal to or greater than the motor rated current.

*

3

This value assumes a carrier frequency of 2 kHz to Swing PWM. Increasing the carrier frequency requires a reduction in current.

*

4

Rated output capacity is calculated with a rated output voltage of 220 V.

*

5

This value assumes a carrier frequency of 10 kHz. Increasing the carrier frequency requires a reduction in current.

*

6

This value assumes a carrier frequency of 8 kHz. Increasing the carrier frequency requires a reduction in current.

Voltage class

200 V

Inverter

Model

Three Phase Inverter CIMR-JC2A

0001

0002

0004

0006

0010

0012

0020

Single Phase*

1

Inverter CIMR-JCBA

0001

0002

0003

0006

0010

Inverter output

Motor output kW at normal duty*

2

0.2

0.4

0.75

1.1

2.2

3.0

5.5

Motor output kW at heavy duty *

2

0.1

0.2

0.4

0.75

1.5

2.2

4.0

Rated output current at normal duty [A]*

3

1.2

1.9

3.5 (3.3)

6.0

9.6

12.0

19.6

Rated output current at heavy duty [A]

0.8*

5

1.6*

5

3*

5

5.0*

5

8.0*

6

11.0*

6

17.5*

6

Overload

120% for 60 sec at normal duty, 150% for 60 sec at heavy duty

from inverter rated output current

Rated output power*

4

at normal duty [kVA]*

3

0.5

0.7

1.3

2.3

3.7

4.6

7.5

Rated output power*

4

at heavy duty [kVA]

0.3

0.6

1.1

1.9

3.0

4.2

6.7

Max. output voltage

Three-phase power supply: three-phase 200 to 240 V (relative to input voltage)

Single-phase power supply: three-phase 200 to 240 V (relative to input voltage)

Max. output frequency

400 Hz

Inverter

input

Rated input voltage

Three-phase 200 to 240 V +10%/-15% , Single-phase 200 to 240 V +10%/-15%

Rated input frequency

50/60 Hz, ±5%