Operating Instructions

MT6 S/2

8

ᕡ Testing probe

ᕢ Button

ᕣ High intensity LED

ᕤ Screw

ᕥ Open

ᕦ Close

ATTENTION:

With the exception of the batteries, never attempt to
remove any components from the device.
Do not use the device if the screw has been removed.
Tighten the screw completely (clockwise).

Prior to Use

Self Test

Before each use of the device, a self
test must be performed in order to
assure correct function. Just touch
the probe with one hand and the
screw on the device with the other.
The blinking of the LED indicates

that the device is functioning correctly.
If this does not happen, stop using the device.
When the LED starts to weaken, the batteries need to
be replaced!

Voltage Test (Alternating Current)

(1) direct voltage test
(70-250 VAC)

ATTENTION!

As soon as the probe is in direct
contact with the external conductor
(phase) of electrical outlets, the LED

blinking.
Note: For this test method we recommend that you not
touch the screw on the device.