PIR 240 IP44 V2

TROUBLESHOOTING AND USER HINTS
Problem:
Light doesn’t come on when there is motion in the moni-
tored area.
Possible Cause 1:

Suggested solution:

No power

Check all connections and

fuses/switches

Possible Cause 2:

Suggested Solution:

Nearby

re-aim sensor or move unit

lighting is too bright

or turn the LUX-setting dial toward (

).

Possible Cause 3:

Suggested Solution:

Control elements

Check setting dial

set wrong
Possible Cause 4:

Suggested Solution:

Sensor is aimed

Re-aim the sensor

in wrong direction

Problem: Light activates for no apparent reason (false alarm)
Possible Cause 1:

Suggested Solution:

Heat sources such as

Aim sensor head away from these

sources.
air conditioners,
air conditioning ducts,
exhaust vents, other
external lighting, running
cars activate the sensor.
Possible Cause 2:

Suggested Solution:

Animals e.g martens

Re-aiming the sensors can help.

or house pets.
Possible Cause 3:

Suggested Solution:

Interference from

Check switches and replace

activation/deactivation

defective switches.

of fans or lights

Replace defective lights

on the same

and/or starters.

circuit as your

Run the light on a

Light.

separate circuit

Possible Cause 4:

Suggested Solution:

Reflections from pool

Re-aim the sensor

or from reflecting
surfaces.