Installation instructions, 7 specifications - heat pump, Dielectric passed – Dometic 39626.501 User Manual

Page 10

background image

INSTALLATION INSTRUCTIONS

10

System Model

39726.501 & 39726.506*

Nominal BTU Capacity

26,000

Volts/Phase/Hertz (each circuit)

115 AC / 1 / 60

Run Amps Comp

(Circuit 1 =10.0)

(Circuit 2 = 9.8)

LRA Compressor

(Circuit 1 = 59.0)

(Circuit 2 = 59.0)

Total Blwr/Fan Motor Run Amps

8.5 (Circuit 1)

Total Blwr/Fan Motor LRA Amps

18.0 (Circuit 1)

Duct Static - Min. ( In. Water Column)

0.40

Duct Static - Max. ( In. Water Column)

1.20

Generator Size Per/Unit - Min. ***

7.5K

Wire Size (Up to 24 ft.)**

(Circuit 1) No. 10 AWG Copper Conductors)

(Suggested)

(Circuit 2) No. 12 AWG Copper Conductors)

Circuit Protection

(Circuit 1) 25Amp

Time Delay Fuse or

(Circuit 2) 15Amp

HACR Circuit Breaker

Control Voltage

12V DC

Refrigerant

R-22

System Refrigerant Charge

(Circuit 1 = 46.5)

(Circuit 2 = 38.5)

Size (In Inches)

Width

Height

Depth

46

18

22

Installed

205 Pounds

Weight

2.7 SPECIFICATIONS - HEAT PUMP

**

Models ending with .506 suffix and manufactured with "SIDE AIR DISCHARGE".

For wire lengths over 24 ft. consult the National Electric Code for proper sizing.

The Manufacturer gives only general guidelines for generator requirements. These generator
requirements come from experiences consumers have with our equipment in field applications.
When sizing the generator, the total electrical power must be taken into consideration. Keep in
mind that generators lose power because of altitude increases above sea level , high outdoor
temperatures and lack of maintenance.

*

***

2.6 WIRING DIAGRAM 39726.501 & 39726.506

VIO

BLK

VIO

BLK

RUN
CAP

CAP

START

COMP

STARTER

STARTER

CAP

START

COMP

HERM

C

USE COPPER CONDUCTORS

USE COPPER CONDUCTORS

WHT

G-Y

BLK

ONLY

115 VAC 60 Hz 1O

115 VAC 60 Hz 1O

CIR.#2

GRY

G-Y

ORN

BLKHD

GRY

WHT

GRY

ON

3 AMP FUSE

NATIONAL ELECTRIC CODE

NATIONAL ELECTRIC CODE

F1

USE COPPER CONDUCTORS

USE COPPER CONDUCTORS

BLK

ONLY

COMPLY WITH THE

COMPLY WITH THE

FIELD WIRING MUST

FIELD WIRING MUST

115 VAC 60 Hz 1O

115 VAC 60 Hz 1O

CIR.#1

P3

SENSOR

AMB.

P2

P1

G-Y

WHT

NC

NO

ORN

WHT

BOX

ELEC.

YEL
YEL

BLU
BLU

RED

BLK

P6

ORN

COM

WHT

BLK

MOTOR
CAP

BLK

ELEC.

BLKHD

BOX

BLK

NC

NO

FREEZE

CONTROL

P5

P4

6

DIP SWITCHES

2

1

5

4

3

K1

8

7

COM

ORN

T3

K6

T2

BOARD

CIRCUIT

T4

G-Y

G-Y

WHT

RED

T1

FAN

WHT

COND. BLOWER

COND. BLOWER

MOTOR

RED

BRN

CAP

RUN

HERM

BRN

WHT

BLK

= WIRE NUT

= WIRE NUT

FACTORY WIRING

FIELD WIRING

FIELD WIRING

BRN

COMPRESSOR

3108345.095

3108345.095

S

C

R

OL

COMPRESSOR

WHT

BRN

BRN

BRN

WHT

BLK

GRY

EVAP. COIL

EVAP. COIL

VIO

BLK

BLK

WHT

C

WHT

RED

WHT

RED

RED

WHT

BRN

VIO

BLK

BRN

BLK

MOTOR

EVAP. BLOWER

EVAP. BLOWER

WHT

WHT

ORN

ASM

VALVE

REV.

REV.

ASM

OL

C

BLK

VALVE

REV.

RED

S

R

DIELECTRIC

PASSED

This manual is related to the following products: