beautypg.com

American Weigh Scales (AWS) CP3-650 User Manual

Page 4

background image

6. You may now remove the sample quantity and add

any amount of the material to the platform, and the

display will show a count.

7. You can switch between weighing and counting

mode by pressing [

PCS

] or [

UNITS

] respectively.

IV. CALIBRATION

Calibration is NOT required before first use. Only

calibrate if scale is not weighing properly.

**The CP3-650 calibrates with a 500g weight (not

included). The CP3-100 calibrates with a 100g weight

(not included)**

1. Turn the scale ON.

2. Hold the [

UNITS

] key for a few seconds. The

display will show "CAL".

3. Press the key again. "CAL" will flash, followed by

the required calibration weight (ie. 500g).

3. Place the calibration weight onto the platform.

4. The display will show "PASS" then return to normal

weighing mode. Calibration is complete!

V. TROUBLESHOOTING

[Display] Elimination of errors

-----------------------------------------------

[OUT2] Recalibrate the scale (Section IV).

[EEEE] You are overloading the scale. Remove the

excessive load immediately!

[un2T] Use the scale in a more stable position