beautypg.com

American Weigh Scales (AWS) SR-1KG User Manual

Page 4

background image

2. Remove the battery cover and locate the calibration

switch to the left of the battery compartment.

3. Switch it to the up position.
4. Press the [ ] button to turn the scale on. A

random number will be displayed.
5. Tap the [ ] button once more and the display will

flash “CAL” folowed by the required cal. weight.

6. Hang a the required weight on the scale’s hook,

keeping the scale as steady as possible.

7. The display will show “PASS” and then return to

normal weighing mode.

8. Flip the calibration switch to the down position and

replace the battery cover.
9. Press and hold the [ ] key to turn the scale off.

IV. TROUBLESHOOTING

The primary reasons for inaccuracy or malfunction

are low batteries, incorrect calibration, overload or

operating on an unstable surface. Please keep this in

mind and maintain and operate your scale properly.

This scale is a precise instrument and must be

handled with the utmost care and caution.

[Display] Elimination of errors

[Lo] Change the batteries.

[OUE2] Recalibrate the scale as shown above.

[EEEE] You are overloading the scale. Remove the

excessive load immediately!

This manual is related to the following products: