VIII. Adjustment

1. Turn the scale on by pressing the ON/OFF key.
2. Wait for the display to show “0.0g” or “0.00g” then

press and hold the MODE key until the display

shows “CAL”, then release.

3. Press the MODE key again. The display will flash

“CAL” followed by the required calibration weight.

4. Place the required calibration weight on the center

of the platform. The display will show “PASS” then

return to normal weighing mode. Calibration is

complete! You may now turn the scale off.

IX. Troubleshooting

Problem: Scale will not turn on

Solution: Check the batteries

Problem: Displayed weight fluctuates randomly

Solution: Make sure your workspace is stable and

free of any air currents or vibration

Problem: Displayed weight is inaccurate

Solution: Perform a calibration adjustment

X. Error Codes

1. OUTZ - Zero range has shifted. Perform calibration

adjustment. If the problem persists, the load cell may

be permanently damaged due to overloading.

2. 88888 - Maximum capacity exceeded. Remove the

extra weight to avoid damaging the load cell.

3. L - Batteries are low. Replace the batteries.