PROGRAMMING MODE
PROGRAMMING MODE
Serial
This allow configuration of Com3 communication parameter i.e. Baud rate, Data Bit,
Parity Bit and Stop bit of the controlled AV Switcher.
Default Parameter for AVS-1200SV2 is as followed:
Baud Rate: 9600
Data Bit: 8
Parity Bit: None
Stop Bit: One
Setting can be easily done with its individual drop list.
Bard Rate: 1200 to 115200
Data Bit: 7 or 8
Parity Bit: None or Odd or Even
Stop Bit: one
Layer
Notice that the Layer function is mask off, which means that Com Port 3 can only, allows
single layer command to be configured.
Hex Code
Command code entry for the relative button, only Hex Code is allows
Transmitter
Note that Com 3 ONLY allows Serial RS-232 transmission, No IR is allows in this case.
1.3 Infrared Tab
This allows user to configure/Learn the IR command code of the Controlled projector in the case where
RS-232 is not available.
1.4 Macros Tab
Macros allows any buttons/fucntion to be link to either Power ON or Power Off button after specific
delay time from 5 to 10 sec.
Example: After Power ON set projection screen Down with delay of 5 sec and set projector default
input select to VGA with another 5 sec of delay.