5.Make sure the two holes shown in fig. 32 are not

blocked. If necessary, clean with a pin.

6.Replace the steam nozzle by inserting it in the steam

tube, lining up arrow A and notch B shown in fig.
33.

7.Replace the cappuccino frother by inserting it as far

as it will go into the steam nozzle, lining up arrow C
and notch B as shown in figure 34 and then rotating
counter-clockwise.

HOT WATER PRODUCTION
1.Turn the appliance on by rotating the selector knob to

the position (fig. 14).

2.Place a container under the cappuccino maker.
3.When the OK indicator light comes on, position the

selector knob as shown (fig. 17) and at the same
time, rotate the steam knob counter-clockwise (fig.
30). Hot water is delivered from the cappuccino
frother;

4.To interrupt delivery of hot water, rotate the steam

knob clockwise and position the selector knob to
"O".

CLEANING AND MAINTENANCE

1. When cleaning the coffee machine, do not use solvents or

abrasive detergents. A soft, damp cloth is sufficient.

2. Clean the filter holder cup, filters, drip tray and water tank

regularly.

IMPORTANT: During cleaning, never immerse the coffee
machine in water. It is an electrical appliance.

CLEANING THE FLAVOR SAVOR
To facilitate cleaning of the Flavor Saver, it can be removed
from the filter holder (R) by pulling it upwards (fig. 35). To
replace, just slide the Flavour Saver into the guides on the
inside edge of the drip coffee filter holder.
CLEANING THE FILTER HOLDER FOR GROUND COFFEE
About every 300 coffees, clean the filter holder for ground
coffee as follows:
• Extract the filter with frother from the filter holder (fig. 36).
• Unscrew the cap of the frother by rotating in the direction

indicated by the arrow on the cap (fig. 37). Remove the
frother from the container by pushing it from the cap end
(fig. 38).

• Remove the gasket and the metal filter (fig. 39).
• Rinse all components and clean the metal filter thoroughly

in hot water using a brush (fig. 40). Check (inspecting
against the light) that the holes in the metal filter are not
blocked. If necessary, open them using a pin (fig. 41).

• Replace the filter and gasket on the plastic disk.. Make sure

to insert the pin on the plastic disk into the hole in the
gasket (hole A in fig. 42).

• Replace the resulting assembly in the steel filter container

(fig. 43), making sure the pin is inserted into the hole in the
support (hole B in fig. 43).

• Finally, screw on the cap.
Failure to clean as described above invalidates the warranty.
CLEANING THE POD FILTER HOLDER
About every 300 coffees, clean the filter holder for pods as
follows:
• Push the filter holder button and remove the filter (fig. 44).

Clean the inside of the filter holder. Never wash in a
dishwasher.

• Clean the filter thoroughly in hot water using a brush. Make

sure the holes in the metal filter are not blocked. If necessary,
clean with a pin (see fig. 41).

• Replace the filter.
Failure to clean as described above invalidates the warranty.

CLEANING THE BOILER OUTLET
About every 300 coffees, the espresso boiler outlet must be
cleaned as follows:
• Make sure the appliance is not hot and that it is unplugged

from the outlet;

• Using a screwdriver, unscrew the screw fixing the espresso

boiler outlet (fig. 45);

• Clean the boiler with a damp cloth (fig. 26);
• Clean the outlet thoroughly in hot water using a brush.

Make sure the holes are not blocked. If necessary, clean
with a pin.

• Continue to clean the boiler outlet while rinsing under the

tap,

• Replace the boiler outlet.
Failure to clean as described above invalidates the warranty.

DESCALING THE ESPRESSO UNIT

You are recommended to descale the coffee machine about
every 300 coffees. You should use a commercially available
product specifically for descaling espresso coffee machines. If
you cannot obtain such a product, you can also follow the
procedure below.
1.Fill the espresso water tank with 1 litre of water.
2.Dissolve 2 spoonfuls (about 1 oz.) of citric acid;
3.Rotate the selector knob to the position and wait

until the OK indicator light comes on.

4.Make sure the filter holder is not attached and

position a container under the outlet.

5.Rotate the selector knob to the position (fig. 17)

and run off half the solution in the tank. Then
interrupt the flow by rotating the selector to the "O"
position (fig. 23).

6.Leave the solution to work for about 15 minutes, then

run off the rest of the water in the tank.

7.To eliminate residues of the solution and scale, rinse

the tank well, fill with clean water and replace in its
housing.

11